AT-5S flat-panel TV monitor luminance and color characteristics auto measurement Table

 
 

1Products:

. AT-5S color flat-panel TV monitors color performance auto measurement system is composed of integrated test platform, computers, control software, and so on. Coordinate with color luminance meter and signal source to measure small to large size LCD TV display's luminance , Chroma and uniformity, contrast, viewing angle, white balance errors, gamma curve, color triangle and so on, and to capture test point coordinates (x, y), by increasing the appropriate accessories to measure the response time. With SJ / T 11343-2006 LCD digital TV universal norms (General Specification for Digital Television LCD displays) and digital TV SJ/T11348-2006 flat panel displays measuring method (Methods of Measurement for Digital Television Flat Panel Displays), the latest national standard, etc.

2、Measurement project

This project automatically measure the following indicators of GB:Table 1

No.

Item Name

Units

GB request

Detection equipment

1

Luminance

cd / m2

= 350

AT-5S

System

Automatic

measurement

2

Contrast

Times

= 150: 1

3

Chroma nonhomogeneity

 

= 0.015

4

Luminance nonhomogeneity

%

= 75

5

Light leakage

cd / m2

= 4

6

White chroma error

9300

 

K

u '= 0.189 ± 0.015

 

v '= 0.447 ± 0.015

White chroma error

6500

 

K

u '= 0.198 ± 0.015

 

v '= 0.468 ± 0.015

7

White chroma nonhomogeneity (? u ', ? v')

 

= 0.015

8

A ngle of visibility (L 0 / 3) - horizontal

(°)

= 120

A ngle of visibility (L 0 / 3) - Vertical

(°)

= 80

9

Color triangle coverage rate

%

= 32

10

White Balance error (? u ')

 

= 0.020

White Balance error (? v ')

 

= 0.020

11

Relations of Luminance non homogeneity and view angle

%

= 50

12

Relations of Chroma uniformity and view angle (? u ')

 

= 0.020

Relations of Chroma uniformity and view angle (? v ')

 

= 0.020

13

Definition

PF-income

Level

Thread

= 350

Signal

source

generates

images

 

 

 

detect

by

eyes

Vertical

= 450

SDTV

Level

= 450

Vertical

= 450

HDTV

Level

= 720

Vertical

= 720

14

Rending rate

AV income

Level

%

= 95

Vertical

Y / C

Level

Vertical

Y, Pb, Pr

Level

Vertical

15

Pixel defects

nonluminous

cell defects

Area A

 

= 2

Area A + B zones

 

= 8 (1 / 9 screen high × 1 / 9 wide screen area can not present two nonluminous points, green or white)

nonextinct

cell defects

Area A

 

0 (white luminous points, or green ones)

= 1 ( red and blue or else luminous points)

Area A + B zones

 

= 2 (1 / 9 screen high × 1 / 9 wide screen area can not present two green or white luminous points)

16

Intrinsic resolution

Pixels

 

17

Trailing time of motion picture

ms

= 20

18

Response time

 

 

increase enclosure to measure

3、Automatic measurement Table

(1) Rotate table

. The rotate table can make the measured TV set on it rotate along the horizontal or vertical direction.

. Rotary perspective: = ± 85 °; angle error: = 0.2 °.

. Rotating platform is convenient to facilitate the installation of 14 to 60 inches LCD (PDP) TV monitor, measuring load not less than 120 kg .

(2) Automatic test platform

. Make the color luminance meter Installed above it move along x, y, z three-dimensional directions.

. x, z effective movement distance: = 1350mm ; y effective movement distance: = 950mm .

. Movement distance error: = 0.3mm .

(3) Computer and control box

. IPC as the core of work, runs measurement software. Control box controls two-rotation and three-dimensional automatic movement.

(4) Measurement software

. Auto measure the items as shown in Table 1 of 1 to 12 of the new national standard.

. The instrument can be connected with CS-200, CS-1000, PR-6500, SR-3, and so on. Can also be connected to a signal source MASTER, MIK, ASTRO, and so on.

4、Response time measurement

. Using specialized response time measurement probe, analysis board, signal sources and measurement software to measure. The system installed in the IPC. Measurement error: = ± 0.5ms.

5、Testing environmental requirements

. In the darkroom, stray light luminance = 1 Lx; environment temperature: 15 ? ~ 35 ? , Optimum temperature: 20 ? ; relative humidity: 5% to 75%; venues: up to six meters long, more than four meters wide, taller than 2.4 meters.

 

 

PDF DOWNLOAD

       
   

 

 
 

Copyright Hangzhou Scirise photoelectricity Co.,Ltd All Rights Reserved. ©Copyright

Address: Room 3-325 of Photoelectric Department , No.38 ZheDa Road , Hangzhou City , Zhejiang Province, China